Database notes indicating possibly erroneous readings/entries:
year,month,day: notes:
2010,01,05: 50cm 4.8 too high, changed to 3.8"
2010,01,06: deep snow causing problems
2010,01,07: deep snow causing problems
2010,01,08: deep snow causing problems
2010,01,09: deep snow causing problems
2010,01,10: deep snow causing problems
2010,02,04: rainfall recorder appears stuck; set duration=x
2010,02,20: register gives sog=1, obs sheet=4
2010,03,19: obs give bare soil min 3.9; suspect
2010,03,20: obs say bar soil min 2.1; error
2010,06,03: tank evap value suspect 0.40
2010,06,04: tank evap value suspect 11.38
2010,06,23: 100cm/14.9 too high; changed to 13.9
2010,07,08: MO visit, various new therms incl plastic 30cm earth tube installed
2010,07,09: observer did not turn up; values estimated; ROW split over two days
2010,07,12: register gives rain as 2.3; 2.2 on obs sheet
2010,07,18: register 100cm/17.6 too high; changed to 16.6
2010,08,22: evap tank reading error
2010,08,23: evap tank reading error
2010,08,29: 0.6h of rain agrees with rainfall chart
2010,09,13: tank evap suspect
2010,09,28: ROW 634.0 in obs sheet; too high cf max gust
2010,10,21: all cc2 values changed from here after it was realised that incorrect metfidaas/mode software means run of wind therein refers to 09-09CT and not 09-09GMT
2010,10,27: evap tank reading suspect
2010,11,20: Piche obs says -0.1; reset to x as even Maidenhead had piche evap>0
2010,11,27: evap tank reading suspect - was there ice?
2010,12,11: evap tank suspect - ice